Edmond, OK Air Conditioning, Heating, Electrical and Generators Service

Air Conditioning, Heating, Electrical and Generators Service in Edmond, OK

Above and Beyond Heating, Cooling and Electrical provides air conditioning, heating, electrical and generators, installation and services in Edmond OK and surrounding areas. Check out what some of our customers are saying about Above and Beyond Heating, Cooling and Electrical air conditioning, heating, electrical and generators services. Contact us today to schedule service, repair or installation.

Local Reviews
for Edmond, OK

Rated 5.0 out of 5 stars based on 92 customer reviews

Map of Edmond, OK

Excellent





Map of Edmond, OK

Great Service




The reminder system is helpful and showed a picture of the technician that would be coming to the house. He was knowledgeable and was able to troubleshoot quickly. We had resolution quickly and I was able to go on with my day.


Map of Edmond, OK

Awesome service!!!!





Map of Edmond, OK

Amazing Company





Map of Edmond, OK

Found the problem




Great Service and price was great!


Map of Edmond, OK

Excellent Prompt Service




Honest, prompt and excellent service at a fair price. They came when they said on a Saturday when my heat went out. They never charge overtime. They are smart, because their fair honest pricing means when I need to replace my HVAC I will go to them. They give free second opinions as well. Very happy.


Map of Edmond, OK

Greart service





Map of Edmond, OK

Furnace Repair




It's seems trouble always happens right before the weekend. Our furnace broke down on very cold Thursday after 5pm. I called Jason with Above & Beyond. He said a tech would arrive by 10am the next morning. The repair tech arrived exactly on time and diagnosed the problem in just a few minutes. He ordered the needed part locally and picked it up from the supplier in less than an hour. He had the furnace up and running within 20 minutes of his return. The price was very fair. I was very impressed with this repair tech and Above & Beyond.


Map of Edmond, OK

Awesome service





Map of Edmond, OK

Great service




Fast, friendly, and convenient


Jesse E.

Jesse E.

System giving code 13 which is limit circuit lockout, the high limit switch was tripped... filters were clogged, changed filters and system was heating well.. the high limit was close to being out of tolerance.. I recommend replacing Replaced both high limit controls

Near Iron Ln, Edmond, OK 73012
Jesse E.

Jesse E.

Upon arrival system gave code for system lockout, filters are dirty, control board is not sending power to gas valve at all times... it’s hit or miss when it works, it may work multiple times but eventually it stops for awhile and causes system lockout.. control board needs replaced and we will take extra off for no finding issue faster

Near Brookhaven Dr, Edmond, OK 73034
Jesse E.

Jesse E.

Upon arrival heater was turned off and pressure switch was make shift jumpered so I plugged pressure switch back up properly and started system and it fired right up, I cycled thru system multiple times to ensure system was working properly and system fired up everytime I checked all 4 limit control and they all work correctly, also checked blower amps and the system is working as it should

Near N Smythe Ave, Edmond, OK 73034
Jason B.

Jason B.

Customer called with complaint of heater not working. We previously had been to the helmet two months ago and found no issues when heater was doing the same thing. No service call charge your dispatch charge on this trip due to previous call with no symptoms found. On this call found that the gas valve is not opening in allowing gas to flow to the burner. Gas valve was getting voltage but would not open. Replaced gas valve with OEM part. Checked for gas leak with combustible gas detector and found no presence of gas. Checked with leak detection liquid and found no gas leak present. Heater is working correctly with no other issues found.

Near Brookhaven Dr, Edmond, OK 73034
Jesse E.

Jesse E.

Cleaned flame sensor, checked limits (3), checked blower capacitor 15uf= 14.6 , blew out pressure switch hose, checked blower amps running 8.7 max per data plate is 9.5, checked inducer draft motor amps 1.3 max per data label is 1.71, checked temp rise 69 return 112 supply, used customers filters to change the filters, checked home for CO 0ppm, system is heating the best it can right now, customer stated that he changed filters a week ago and filters were dirty today- also stated that system would come on and run for 5-10mins then shut off a week ago before he changed filters, I notified customer that he should call us back when problem is occurring Check to see if customer qualifies for oge cool saver program

Near Sand Plum Dr, Edmond, OK 73025
Jesse E.

Jesse E.

Upon arrival control board gave code that pressure switch was stuck closed, so I blew thru hose and ports to be sure that they were clear and then I started up system and it fired right up but as I cycled through system to ensure it would work continuously I noticed that the pressure switch would still stick about every 3rd time Replaced pressure switch and system is heating as it should

Near Promontory Rd, Edmond, OK 73013
Jesse E.

Jesse E.

Upon arrival I found that the pressure switch was stuck closed so I jumpered wires and system fired right up... replaced pressure switch system heating when I left

Near NW 167th St, Edmond, OK 73012
Jesse E.

Jesse E.

Found that molex plug has wiggles loose on control board cause system not to make it thru heating cycle... plugged molex plug back in and system is running well, I recommend replacing control board but it’s not 100% necessary.. also noticed that the blower capacitor is out of tolerance and will need to be replaced because it’s already causing blower motor to make a noticeable noise on the startup

Near NW 168th St, Edmond, OK 73012
Jesse E.

Jesse E.

Blower motor not turning. Motor would not run, causing heater to shut off on high limit. Replaced motor with OEM motor and unit heating home. Replaced blower motor and tightened gas union to stop leaking System heating when I left

Near Bristol Ln, Edmond, OK 73034
Jesse E.

Jesse E.

High limit is stuck open, changed out high limit and roll out Also checked home for CO - System heating well when I left temp has raised from 57 degrees to 68 degrees

Near Scarlet Oak Ln, Edmond, OK 73012
Jesse E.

Jesse E.

Changed filters and that stopped our whistling noise, cleaned flame sensor bc it had quite a bit of corrosion built up, checked blower capartment to be sure it was clean and no obstructions

Near Bridlington Dr, Edmond, OK 73012
Jesse E.

Jesse E.

Mechanical Rough-In

Near Coffee Tree Cirle, Edmond, OK 73012
Jason B.

Jason B.

Heater not working. Capacitor bad and not allowing motor to run. Blower motor bearings have wear and making noise.Notified owner of issue and provided quote. Replaced capacitor and unit running normally.

Near Bristol Ln, Edmond, OK 73034
Jason B.

Jason B.

Heat not working. Found induced draft motor shield broken. Motor not turning. Checked motor and found bearings worn. Will call Monday to check warranty status and availability.

Near NW 184th St, Edmond, OK 73012
Jesse E.

Jesse E.

10year parts warranty 2year labor warranty New furnace, coil, condenser.. also add in 2- 10x20 filter grills Couldn’t get filter grills installed because 2x4 are in the way so we just installed new filters

Near N University Dr, Edmond, OK 73034
Jesse E.

Jesse E.

Installed 10ft of 6” duct, fixed hot water tank flue, changed filter 14x24, check blower capacitor, checked limits, checked igniter, cleaned flame sensor, evaporator coil, checked blower amps Checked outdoor unit components for operation. Ac starts up, but it’s too cold outside to obtain correct readings on unit. Rust was found on coil, but no leaks were found using electronic leak detector or using bubble method. Heater was operating as designed and no issues found.

Near Gateway Dr, Edmond, OK 73013
Jason B.

Jason B.

Cut out hole for upstairs closet supply Customers father stated that he had the grill and would put it up himself

Near Blossom Ct, Edmond, OK 73012
Jesse E.

Jesse E.

Condensate drain has melted in, 6” duct running from system to roof has completely fell apart, coil is really dirty can try to use spray cleaner, blower capacitor is completely out reading zero, blower motor has winding out

Near Heidi Rd, Edmond, OK 73012
Jesse E.

Jesse E.

Low voltage issue with her smoke detector that’s pluggged into downstairs furnace plug, unplugged and problem stopped Control board sending 120volts to igniter but igniter not coming on, replaced igniter and heater working well Customer wouldn’t allow me in house only in garage

Near NW 153rd Terrace, Edmond, OK 73013
Jesse E.

Jesse E.

Carrier system giving me lockout code 13 for high limit control Filters were really clogged changed filters on system and system ran just fine

Near Hill Valley Way, Edmond, OK 73012
Jesse E.

Jesse E.

Control board sending 24volts to gas valve and gas valve is stuck closed- bad gas valve Installed new gas valve and system heating well when I left

Near NW 197th St, Edmond, OK 73012
Jesse E.

Jesse E.

Control board sending 120volts to inducer draft motor and motor not coming on... bad inducer draft motor Installed new draft motor and system was heating when I left

Near Vermejo Dr, Edmond, OK 73012
Jesse E.

Jesse E.

Customer said that system has been working good today, high efficiency system in attic, drain has a bow in it and I recommend adding heat tape to keep drain from freezing during cold winter days(could’ve been problem yesterday) also filters are pretty clogged offered to change them but homeowner said that her husband would take care of that, cleaned flame sensor, checked limits, checked blower amps, checked igniter, blew out pressure switch hoses, system fired right up, cycled through system to ensure it was working good System heating when I left

Near Josiah Pl, Edmond, OK 73013
Jesse E.

Jesse E.

Upon arrival system was giving me a lockout code for trying to start too many times with an issue so I pulled power and cleaned flame sensor, cleared pressure switch hose, checked limits and rollouts, checked igniter, checked blower amps, changed filters (with customers filters 12x24x1); coneected power back and system started right up, checked home for CO 0ppm after 15-20mins of running, system blowing 102.6 degree air, cycled through system multiple times and system is working as it should

Near Brookhaven Dr, Edmond, OK 73034
Jesse E.

Jesse E.

Cleaned pressure switch ports, checked limits, cycled thru system to ensure its working good and system fired up every time

Near Peacock Dr, Edmond, OK 73012